INVERTERS
Because each solar panel has maximum power point tracking, power optimizers can be installed with solar panels to generate more electricity.
Because each solar panel has maximum power point tracking, power optimizers can be installed with solar panels to generate more electricity.
The power optimiser, developed by SolarEdge, revolutionized solar system power harvesting and management.
Power optimisers, inverters, and a monitoring platform make up a SolarEdge system.
SolarEdge has recently added critical power, automation machines, batteries, e-mobility, and panels to its product line. As a result, SolarEdge is now one of the world’s largest and most diverse solar technology businesses.
get a quoteCompatible with LG Prime and SolarEdge Battery Bank Backup function is availbe with Solaredge backup box
Single inverter for managing PV production,
battery storage and backup power
Designed to eliminate high voltage during installation, maintenance or firefighting
Built-in monitoring of battery status, PV production, remaining backup power, and self-consumption data
Remote access to inverter software
Specifications |
---|
Rated AC Power Output: 4985VA |
Max AC Power Output: 4985VA |
AAC Output Voltage (Nominal), L-N(2) 220 / 230 Vac |
AC Output Voltage Range, L-N 184 - 264.5 Vac |
AC Frequency 50 / 60 ± 5 Hz |
Maximum Continuous Output Current: 27A |
Residual Current Detector / Residual Current Step Detector 300 / 30 mA |
Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes |
Charge Battery from AC (if Allowed) Yes |
THD <3 % |
Power Factor With Rated Power >0.99 (configurable; 0.8 leading to 0.8 lagging) |
Typical Nighttime Power Consumption <5 W |
Rated AC Power Output Lower of: 4985, battery max power VA |
Max AC Power Output - Surge Lower of: 6600, battery max power VA |
AC Output Voltage (Nominal) 220 / 230 Vac |
AC Output Voltage Range 184 - 264.5 Vac |
AC Frequency 50 / 60 ± 5 Hz |
Maximum Continuous Output Current 22 A |
AC Breaker Yes |
THD <5 % |
Power Factor With Rated Power 0.2 leading to 0.2 lagging |
Automatic Switchover Time <2 sec |
Transformer-less, Ungrounded Yes |
Max Input Voltage 500 Vdc |
Nom DC Input Voltage 400 Vdc |
Reverse-Polarity Protection Yes |
Ground-Fault Isolaiton Detection 600kΩ Sensitivity |
Maximum Inverter Efficiency 97.6 % |
European Weighted Efficiency 97.4 % |
AC Output (Loads/Grid) conduit size / wire cross section 32mm / 4-14mm2 |
AC Output (Backup) conduit size / wire cross section 25-32mm knockout / 4-14mm2 |
DC Input (PV) conduit size / wire cross section 25mm / 4-6mm2 |
DC Input (Battery) conduit size / wire cross section 25mm / 4-6mm2 |
Dimensions with Connection Unit (HxWxD) 962 x 315 x 184 mm |
Weight with Connection Unit 26.5 kg |
Cooling Natural convection and internal fan (user replaceable) |
Noise <50 dBA |
Min - Max Operating Temperature -20 to +60(6) ˚C |